다중이용시설에서의 실내공기중 미생물 분포에 관한 연구

이용수 60

영문명
Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings
발행기관
한국환경보건학회
저자명
김윤신 이은규 엽무종 김기영
간행물 정보
『1. 한국환경보건학회지』제28권 제1호, 85~92쪽, 전체 8쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2002.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m3 was found in the subway station and the lowest concentration of 44cfu/m3 was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m3 was found in the subway station and the lowest concentration of 14cfu/m3 was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m3 was found in the hospital and the lowest concentration of 32cfu/m3 was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김윤신,이은규,엽무종,김기영. (2002).다중이용시설에서의 실내공기중 미생물 분포에 관한 연구. 1. 한국환경보건학회지, 28 (1), 85-92

MLA

김윤신,이은규,엽무종,김기영. "다중이용시설에서의 실내공기중 미생물 분포에 관한 연구." 1. 한국환경보건학회지, 28.1(2002): 85-92

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제