폐쇄성 수면 무호흡증에 있어 두부 규격 방사선 계측학적 기여 인자

이용수 7

영문명
CEPHALOMETRIC PREDICTORS OF OBSTRUCTIVE SLEEP APNEA
발행기관
대한구강악안면외과학회
저자명
권대근(Tae-Geon Kwon) 조용원(Yong-Won Cho) 안병훈(Byung-Hoon Ahn) 서영성(Young-Sung Suh)
간행물 정보
『대한구강악안면외과학회지』대한구강악안면외과학회지 제29권 제5호, 338~345쪽, 전체 8쪽
주제분류
의약학 > 내과학
파일형태
PDF
발행일자
2003.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : This study was intended to perform cephalometric comparison between the patients with and without obstructive sleep apnea (OSA). The factors influencing the OSA in the lateral cephalogram was also investigated. Patient and Method : Twenty four patients who visited Sleep Disorder Clinic in Dongsan Medical Center, Keimyung University and evaluated with polysomnograph(PSG) and cephalogram were included in the study. The patients had apnea-hypopnea episode(AHI) over 10 times per hour was diagnosed as OSA after overnight PSG. To evaluate hard and soft tissue profile, cephalometric radiogram were taken at maximal intercuspation(P1) and mandibular protruding position(P2). The diffefence between the OSA and normal group were evaluated statistically and the stepwise regression analysis was applied to analyse the cephalometric influencing factors to OSA. Result : The OSA Group(n=14) had significantly higher Body Mass Index(BMI) than control group(n=10). Lower facial height(ANSGn) was longer in OSA group. However statistically significant difference was not detected in other anteroposterior craniofacial measurements. The soft palate lenth (PNS-P), hyoid position (MP-Hyoid) had positive correlation between AHI (r=0.496, r=0.413, respectively, p<0.05). However, the measurements of oropharyngeal airway was not different between the two groups. The hypothesis, the antero-posteriorly narrow oropharyngeal airway might aggravate the airway resistance and can give rise to higher AHI, was not accepted in the study. This can be attributed by inclusion of the patients performed uvulopalatopharyngoplasty because of the tonsilar or soft palate hypertrophy in the present study. The results of regression analysis revealed that PNS-P, upper airway width(Nph1), upper facial heght(N-ANS), and lower facial height(ANS-Gn) could influence the degree of AHI (F value < 0.0001, R2 = 0.829). Conclusion : We suggest lateral cephalogram may utilized as a useful method to evaluate OSA. The patient with long soft palate, narrow upper airway width, long upper & lower facial height can be expected to have high risk of OSA. However, it should be emphasized the comphrehensive intraoral inspection including soft palate and tonsilar hypertrophy because lateral cepahlogram cannot visualize oropharyngeal status completely

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

권대근(Tae-Geon Kwon),조용원(Yong-Won Cho),안병훈(Byung-Hoon Ahn),서영성(Young-Sung Suh). (2003).폐쇄성 수면 무호흡증에 있어 두부 규격 방사선 계측학적 기여 인자. 대한구강악안면외과학회지, 29 (5), 338-345

MLA

권대근(Tae-Geon Kwon),조용원(Yong-Won Cho),안병훈(Byung-Hoon Ahn),서영성(Young-Sung Suh). "폐쇄성 수면 무호흡증에 있어 두부 규격 방사선 계측학적 기여 인자." 대한구강악안면외과학회지, 29.5(2003): 338-345

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제