An in vitro comparison between two different designs of sagittal split ramus osteotomy

이용수 0

영문명
An in vitro comparison between two different designs of sagittal split ramus osteotomy
발행기관
대한구강악안면외과학회
저자명
Valdir Cabral Andrade Leonardo Flores Luthi Fabio Loureiro Sato Leandro Pozzer Sergio Olate Jose Ricardo Albergaria-Barbosa
간행물 정보
『대한구강악안면외과학회지』대한구강악안면외과학회지 제41권 제3호, 133~138쪽, 전체 6쪽
주제분류
의약학 > 내과학
파일형태
PDF
발행일자
2015.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objectives: To evaluate the influence of the type of osteotomy in the inferior aspect of the mandible on the mechanical performance. Materials and Methods: The study was performed on 20 polyurethane hemimandibles. A sagittal split ramus osteotomy (SSRO) was designed in 10 hemimandibles (group 1) with a vertical osteotomy in the buccal side (second molar level) and final osteotomy was performed horizontally on the lingual aspect, while the mandible body osteotomy was finalized as a straight osteotomy in the basilar area, perpendicular to the body. For group 2, the same osteotomy technique was used, but an oblique osteotomy was done in the basilar aspect of the mandibular body, forming continuity with the sagittal cut in the basilar area. Using a surgical guide, osteosynthesis was performed with bicortical screws using an inverted L scheme. In both groups vertical compression tests were performed with a linear load of 1 mm/min on the central fossa of the first molar and tests were done with models made from photoelastic resin. Data were analyzed using Student’s t-test, establishing a statistical significance when P<0.05. Results: A statistical difference was not observed in the maximum displacements obtained in the two osteotomies (P<0.05). In the extensiometric analysis, statistically significant differences were identified only in the middle screw of the fixation. The photoelastic resin models showed force dissipation towards the inferior aspect of the mandible in both SSRO models. Conclusion: We found that osteotomy of the inferior aspect did not influence the mechanical performance for osteosynthesis with an inverted L system

목차

I. Introduction
II. Materials and Methods
III. Results
IV. Discussion
V. Conclusion

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Valdir Cabral Andrade,Leonardo Flores Luthi,Fabio Loureiro Sato,Leandro Pozzer,Sergio Olate,Jose Ricardo Albergaria-Barbosa. (2015).An in vitro comparison between two different designs of sagittal split ramus osteotomy. 대한구강악안면외과학회지, 41 (3), 133-138

MLA

Valdir Cabral Andrade,Leonardo Flores Luthi,Fabio Loureiro Sato,Leandro Pozzer,Sergio Olate,Jose Ricardo Albergaria-Barbosa. "An in vitro comparison between two different designs of sagittal split ramus osteotomy." 대한구강악안면외과학회지, 41.3(2015): 133-138

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제