방사광 X-선으로 찰영한 갑상선 조직 영상

이용수 10

영문명
Synchrotron X-ray Microscopic Imaging of Thyroid Tissues
발행기관
대한내분비외과학회
저자명
봉진구 황정연1 박성환 Jin Gu Bong M.D. Jung Yun Huang Ph.D.1 and Sung Hwan Park M.D.
간행물 정보
『The Koreran journal of Endocrine Surgery』10권1호, 19~23쪽, 전체 5쪽
주제분류
의약학 > 일반외과학
파일형태
PDF
발행일자
2010.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: X-ray microscopy with synchrotron radiation will soon be a useful tool for innovative x-ray imaging in clinical and laboratory settings. It enables us to observe the detailed internal structure of human tissue samples with great magnification power and excellent resolution. So, it has the possibility to be used for the clinical and research purposes to investigate thyroid diseases if it can effectively evaluate the various conditions of thyroid tissue. To determine the relation with their optical microscopic features, we compared the synchrotron X-ray images of unstained normal and thyroid cancer tissue samples with the histopathologic findings of their adjacent, stained thyroid tissue sections. Methods: An x-ray microscope was installed on a 1B2 beamline with a Pohang Light Source, which is a 3rd generation synchrotron radiation facility with an operating energy of 2.5 GeV at Pohang, Korea. The x-ray energy was set at 11.1 keV and the x-ray beam was monochromatized using a W/B4C monochromator. Formalin-fixed 10Ռm-thick female thyroid tissues from normal cases and carcinoma cases were attached on Kapton film for the imaging. The sample was positioned 25 m away from the beam source. The x-ray image of the sample was converted into a visual image on the CsI (TI) scintillation crystal, and it was magnified 20 times by the microscopic objective lens. After an additional 10 times digital magnification, this visual image was captured by a full frame CCD camera. Results: The monochromated x-ray microscopic images of the female thyroid tissues of the normal cases and carcinoma cases were obtained with good resolution. These synchrotron images showed the normal follicular structures in the normal thyroid tissue sections and the characteristic severe stromal fibrosis with collagen fiber accumulation in the cancer tissue sections. Conclusion: Owing to the great magnification and excellent resolution, the synchrotron x-ray microscopic images of the normal and cancerous thyroid tissues showed good correspondence with the histopathologic findings of their adjacent, stained tissue sections. So, the x-ray microscopic imaging of thyoid tissue using synchrotron radiation has good potential for use in various clinical and research settings in the future. (Korean J Endocrine Surg 2010;10: 19-23)

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

봉진구,황정연1,박성환,Jin Gu Bong, M.D., Jung Yun Huang, Ph.D.1 and Sung Hwan Park, M.D.. (2010).방사광 X-선으로 찰영한 갑상선 조직 영상. The Koreran journal of Endocrine Surgery, 10 (1), 19-23

MLA

봉진구,황정연1,박성환,Jin Gu Bong, M.D., Jung Yun Huang, Ph.D.1 and Sung Hwan Park, M.D.. "방사광 X-선으로 찰영한 갑상선 조직 영상." The Koreran journal of Endocrine Surgery, 10.1(2010): 19-23

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제