본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교

이용수 139

영문명
A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Intermal Rotation Range of Motion Measurement Methods
발행기관
한국전문물리치료학회
저자명
김현숙(Hyun-sook Kim) 이원휘(Won-hwee Lee) 정성대(Sung-dae Choung)
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제17권 제3호, 1~10쪽, 전체 10쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2010.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide dis tance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder muscu loskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods In two trials, measurements were perfonned on each subject by two examiners. Intraclass correlation co efficient (ICC(3,1)) was used to detennine the reliabiliη of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the 、risual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the expenmental group, the difference of examined range of motion by each examiner was significant in the 、risual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliabiliη of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.

목차

Ⅰ. 서론
Ⅱ. 연구방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김현숙(Hyun-sook Kim),이원휘(Won-hwee Lee),정성대(Sung-dae Choung). (2010).어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교. 한국전문물리치료학회지, 17 (3), 1-10

MLA

김현숙(Hyun-sook Kim),이원휘(Won-hwee Lee),정성대(Sung-dae Choung). "어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교." 한국전문물리치료학회지, 17.3(2010): 1-10

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제